Just a few other services that MWF Plumbing provide: Caravan Gas Certificates, Treatment Plant Services (Ozzikleen, AquaNova etc)

  • image1
  • Treatment Plant Servicing
  • The Ozzi Kleen sewage system is a single tank treatment plant using a cyclic, aerobic treatment process, designed to treat all your household wastewater.

    All local authorities require all types of domestic sewage treatment plants to undergo regular servicing and testing.
    The Ozzi Kleen RP10 wastewater treatment process is factory precision-set to give reliable operation. A periodical 3 month service is to be performed by an Ozzi Kleen RP10 qualified service personnel. At this time a range of performance and water quality tests are performed. Just like a car requires servicing – so does your Ozzi Kleen RP10 to ensure safe and efficient operation.

    A report of this service is sent to your local authority with a copy also issued to you as the Ozzi Kleen RP10 owner. A maintenance log book is kept in the control box of the Ozzi Kleen RP10 sewage treatment system to record the history of the system, both for the owner’s and the service person’s reference.

  • Caravan Gas Certificates
  • To make your caravan gas compliance certificate quicker on the day it is a good idea to run all the appliances, to make sure everything is in working order for the inspection. If an appliance isn't functioning correctly let us know and we will get it fixed.
  • - When using any Gas System you should pick the biggest and easiest appliance and run that first e.g. the Cook Top or Stove as you can purge the stale gas through the lines easily.
    If your caravan was not manufactured in Australia it is a good idea to look at the appliances closely. It will need Australian compliance for each appliance to pass the inspection along with a compliance plate for the installation  

    For your Caravan to pass the gas safety inspection it MUST have the following
    - Compliant 2 Stage Regulator with pressure protection
    - Test Point 

    - Gas Fitters Plate or Gas Compliance Plate
    - Australian Certified Appliances
    - Comply to Australian Standard AS5601

    PLEASE NOTE - ANY EXTRA WORK REQUIRED TO MAKE THE TRAILER OR CARAVAN PASS THE INSPECTION IS AN ADDITIONAL COST TO, AND NOT INCLUDED IN THE INSPECTION FEE.